Case Study: Wind Turbine Control, USA

wind-turbine-control-usa

A major wind power company in the USA uses Skkynet’s Cogent DataHub™ software to deploy an automated solution that temporarily halts turbines during bat migration, ensuring the protection of an endangered species without sacrificing significant energy production. By leveraging DataHub’s scripting capabilities, the company efficiently controls turbine operations based on wind speed and temperature, providing real-time monitoring and minimizing disruptions.

Key takeaways:

  1. Avoids wind farm closure and the loss of associated revenue.
  2. Wind farms operate at optimal capacity.
  3. Avoided extensive reconfiguration costs.
DataHub Scripting solution calms the conflict of bats vs. blades

Required by law to protect a rare species of bat, a major wind power generation company finds a solution using the Cogent DataHub™

A rapid expansion of wind farms across the Eastern and Central United States has been checked in the past couple of years due to growing concerns for wildlife. An endangered bat species lives in that area, and is protected by law. Fears that the whirring blades of wind turbines could be harmful to this species of bat were sufficient to halt construction of a wind farm in West Virginia in 2009, and the discovery of a dead bat near a wind turbine in Pennsylvania in 2011 caused the power company to shut down the whole 35-turbine system for several weeks.

Although wind turbines are known to cause a few fatalities among common tree-dwelling bats, the endangered bat was thought to be largely safe, as it lives in caves, hibernates for more than half the year, and is seldom found in the vicinity of wind turbines. However, in the fall these bats migrate from their feeding grounds to their home caves for the winter. During this time, the chances of them passing through a wind farm are greatly increased.

In March a few years ago a major power company in the USA was informed by the US Fish & Wildlife Service that a number of turbines on the bat migration routes would need to be shut down while the bats are migrating. This caused quite a stir. The migration period for the bats is two months long―from mid-August to mid-October. Shutting down the whole system for that length of time would be very costly, not to mention the loss of clean energy which would need to be replaced by fossil fuels.

To maximize uptime, the company gained permission to let the turbines run during the times that the bats were not flying – all daylight hours, and in the night time when air temperatures drop below a specific temperature setpoint, or when the wind is fairly strong. The challenge was to implement a complete solution. A single bat fatality could mean full shut-down, legal penalties, and even lawsuits.

Top management at the company immediately took action, contacting the wind turbine manufacturer, who also provides the control systems. After several months of emails and meetings, it became apparent that the manufacturer would not have anything ready in time for the mid-August deadline.

“With three weeks to go, they told us there was no solution in sight,” said the SCADA engineer responsible for the project, “and we would need to go to manual operation, and reconfigure the cut-in speed on every turbine, twice a day.”

Most wind turbines are designed to “cut in”, or start turning to produce energy, when the wind is blowing at a certain speed. For these turbines, the normal cut-in speed is 3.5 meters per second. As the bats are active in low to moderate wind speeds, the company would need to raise that to 7 meters per second each night, and then drop it back down to 3.5 the following morning. This would mean manually reconfiguring the PLCs for 100 turbines, twice a day.

A better way

“I thought there must be a better way,” the project manager continued. “We’d been using the DataHub for years, and knew the potential was there to leverage this asset further. I gave Skkynet a call, and told them what we were up against. They delivered by helping us to develop a very efficient program using the native scripting language of the DataHub. The code ran right on the SCADA interface of the OEM system – so it’s as reliable as you can get.”

“Working together with Skkynet, we came up with a DataHub script that doesn’t change the cut-in speed of the turbines at all. We just blocked them from starting. The script tells each turbine to stay off, and keeps measuring wind speed. When it picks up to 7 meters per second, the script releases the turbine to start, and it ramps right up to the operating state. At the end of the day, we have a complete audit trail of every turbine controlled, including a history of critical parameters, such as rotational and wind speeds, and energy curtailed.”

“The script also has a temperature component. On cool nights in September and October, when the temperature drops below the dew point, it uses the same algorithm for starting and stopping the wind turbines.”

By the first week of August a test script was written, and after a few days of testing and last-minute tweaks, it was ready. The system went live on August 15th, and is meeting all expectations. Every night, whenever the air temperature is above the setpoint and the wind speed falls below 7 meters per second, the wind turbines stop, allowing the endangered bats to return safely to their caves for a long winter hibernation.

“I call the DataHub the Canadian Swiss Army Knife,” said the project manager. “We are able to accomplish a host of required functions with a single product solution. The ability to provide sophisticated logic and control algorithms with the built-in functionality of this product is the game changer. Being able to securely deliver real-time data between a site and the control center system allows the dispatch team to monitor the control process and maximize the production of clean, renewable, energy sources. Talk about a smart grid – who would have thought we’d be doing this type of thing in real time?”

Download case study

PDF document

Learn More Try it Now
Share this entry
  • Share on Facebook
  • Share on X
  • Share on WhatsApp
  • Share on LinkedIn
  • Share by Mail
SKKYNET CASE STUDIES

See which solutions to real-world automation problems we deliver for use-cases most relevant to you.

  • Wood processing plant case study - bannerCase Study: Wood Processing Plant in Nor…
  • case-study-heritage-petroleumCase Study: Heritage Petroleum, Trinidad…
  • Case Study: TANAP Pipeline, Turkey
  • Case Study: Renewable Wind Power, Turkey
Learn More Try it Now
About Us Icon white

About Us

Skkynet has been helping organizations securely share real-time data for more than 25 years. We offer privately-hosted or fully managed solutions for moving data in industrial, embedded and financial systems, from anywhere to anywhere.

News

June 18, 2026

Skkynet Reports Q2 FY2026 Financial Results

January 28, 2026

Skkynet Reports Fiscal 2025 Financial Results: Subscription Revenue Surges 268% Amidst Strategic Pivot to AI and SaaS

December 18, 2025

Skkynet Announces C$2.6 Million Industrial AI Product Development Initiative

December 16, 2025

Skkynet Appoints M&A and Software Executive Shaunna Balady to Advisory Board

Contact us icon white

Contact Us

Skkynet
2233 Argentia Road, Suite 302
Mississauga, ON L5N 2X7

International: 1-905-702-7851

US/CA Toll Free: 1-888-702-7851

[email protected]

Skkynet logo white

Cogent DataHub | Industrial | Case Studies | Partners | Investors | About us

Back to Top

linkedIn logotwitter logoyoutube logo

© 2026 Skkynet | All rights reserved | Legal notices
Link to: Case Study: TANAP Pipeline, Turkey Link to: Case Study: TANAP Pipeline, Turkey Case Study: TANAP Pipeline, Turkey Link to: Aarif Nakhooda Joins Skkynet Advisory Board to Drive Innovation in Industrial AI Link to: Aarif Nakhooda Joins Skkynet Advisory Board to Drive Innovation in Industrial AI Skkynet Times NewspaperAarif Nakhooda Joins Skkynet Advisory Board to Drive Innovation in Industrial...
Scroll to top Scroll to top Scroll to top

We are using cookies to give you the best experience on our website.

You can find out more about which cookies we are using or switch them off in .

Skkynet logo
Powered by  GDPR Cookie Compliance
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

3rd Party Cookies

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages.

Keeping this cookie enabled helps us to improve our website.

Cookie Policy

More information about our Cookie Policy